The V12 DUO the ultimate heating system

There are many modern wood burners on the Market that have either factory fitted back boilers or a boiler can be clipped on to the rear of the stove to provide both central heating and domestic hot water.

There are none that benefit from the technology contained in the vesta v12 duo. Vesta have designed a heating solution that is efficient and extremely versatile.

The v12 duo with factory installed stainless steel twin heat exchangers is one of the most efficient wood burners on the market. It boasts an output of 12kw total made up of 6kw to water and 6kw room heating. The duo boilers are constructed from high grade 316 stainless steel and unlike many boilers available on the market will not contaminate the water system with rust or degrade over time.

With 4 x 28mm inlet and outlet ports on the rear of the v12 duo this appliance can be connected onto a gravity feed system or ideally through heating coils on a thermal store. As the duo boilers are constructed in the same way as plate heat exchanges then the flow of heat into the water in very efficient and the start up cycle rapidly brings the water to temperature.

The huge firebox in the v12 makes it the ideal stove to run your hot water systems as the firebox can easily cope with a 400mm log making endless splitting down of large logs a thing of the past. Call us today on 0161 4080431 to discuss how the v12 DUO can be integrated into your hot water system. The V12 Duo is available with log storage box that raises the fire 225mm off the floor and allows logs to be preheated conveniently under the stove.


Calling all Spanish dealers

Due to an increase in web traffic from Spain and the surrounding areas we are now seeking to partner with Spanish retailers to sell our contemporary woodburners. We have already sold a number of stoves to customers in Spain but are now looking to expand our business into these areas. If you are a stove reseller in Spain then please get in touch for an information pack on sales@vestastoves.co.uk.


Cream Wood Burning Stove

Cream woodburning stove

We have noticed a huge increase in the amount of white colored wood burning stoves being searched for over the past few moths, and are often being asked for white wood burners when customers visit our showroom.  We occasionally manufacture white wood burning stoves but we due to the nature of a fireplace or wood burning stove we would normally advise against it.

White wood burners available as a custom option

As you will know burning solid fuels produced lots of ash and tar inside this stove and inevitably this will get on your hands and be transferred to the white wood burner.  White is very difficult to clean so as an alternative our standard light colour is Almond or cream.  Cream wood burning stoves stand up to marking much better than white and also has a longer life span. So if you looking for a white wood burner then why not take a look at our colour chart  and see some of the other alternatives available. If you still are looking for a white wood burner then please call us on 01704 821095 and we will be happy to help.

 

 

 

 

 

 

 

 

 

 


How to install a wood burning stove or logburner

[heading]How to install a wood stove[/heading]

The installation of a contemporary wood burning  stove is a relatively simple process providing some simple principles are followed. The installation of any stove should be taken seriously and a carbon monoxide detector always installed in the room were the stove is situated.

Here is a comprehensive list of the items you will need

If you have a chimney you will require:

  • A Wood stove or multifuel stove
  • A connecting Flue (Colour matched)
  • A register plate
  • A flue liner kit
  • Fire Cement or High Temperature Silicone
  • Carbon Monoxide Detector

[heading]Considerations on how to install a wood burning stove[/heading]

Contemporary wood burners and wood stoves rely on the pressure variation in the chimney or flue to create a natural draught that forces air through the air-wash system and allows the fuel to burn inside the appliance.

Air rises inside the chimney naturally as it is lighter than the air in the surrounding environment, similar to the way a hot air balloon rises into the atmosphere. In order for this process to work correctly the junction between the contemporary stove and the flue or chimney needs to be gas tight and free of leaks were the chimney could suck in colder air and dilute the temperature inside the chimney.

Most commonly, poor performance in a modern wood stove is caused by the failure of the installation to be gas tight or by failure to understand the affect of other environmental issues that can cause interruption or loss of the natural convection taking place inside the chimney system.

It is critical that the flue system is performing correctly on a contemporary wood burner as often they contain a large glass window, providing a better flame picture. If the air wash system isn’t functioning correctly then the glass will become blackened with tar and deposits.

There are also many environmental issues that should be considered prior to installation.

Downdraught caused by a pressure zone in the area if the exiting flue is a common problem when installing a contemporary woodburner, Especially when using a prefabricated twin wall flue system. Often the exit point of the terminal on the roof will be at a point below the ridge of the roof or overlooked by adjoining buildings or trees, or the new terminal is lower than any existing chimneys.

Downdraught problems can be easily overcome by correct planning and siting of the chimney terminal but a balance between functionality length at which a chimney can be extended before looking out of place. Were the Hight of a flue or chimney is restricted then the only option is to install a chimney fan. There are many anti-Downdraught cowls and products on the Market but very few can truly address the problem at cause.

Conservatories pose the most demanding situation for the installation of a contemporary wood burner usually because the house overlooks the wood burner exit terminal and causes a back up of prevailing wind that in worst cases can cause the chimney to work in reverse. Signs of down draught in these cases can be as drastic as filling a room with smoke to small occasional puffs of smoke being emitted from air vents. Downdraught and poor heat output is more common in heavily baffled stoves. The vesta v4 stove is ideally suited for conservatories as it is not heavily baffled.

Installing a closure or register plate

It is essential that a proper fitting closure or register plate is used when installing a stove. This is the most important component and ensures that all the air that is being sucked into the chimney is coming directly through the stove control vents. This ensure that the stove is running at its optimum pressure and that the airwash system can keep the glass clean at all times.

Register plates are made from 2mm steel and painted to suit your flue pipe. They are available in three sizes here

Calculating your requirements

The size of stove required for a building is an important part of the process. Often contemporary wood burners are installed in larger open spaces and consideration should be taken on the total heating requirements. If your unsure about the exact requirement we can advise you accordingly so feel free to call us in 01704 821095.

You can use our kW calculator below to give you an idea of the size you will need:

Siting your contemporary woodburner

The location of you stove will most likely be in an existing chimney breast but as more houses are built without a class 1 chimney then your stove may be located either in the centre of the house with a pre-fabricated flue passing through the roof or on an outside wall with the pre-fabricated flue passing through the outside wall and climbing the building to exit above the gutter. Locating the fire in the centre of the house gives the benefit of extra heating from the flue but perhaps is a little more involved in the installation.

We are able to supply you you with a full range of flue systems colour matched to coordinate your stove or simply blend in with outside fixtures such as downpours etc.

It is important to consult the installation instructions carefully and ensure that the required clearances are built into the planned positioning. All vesta contemporary wood stoves are designed to connect both from the top flue position to be interchanged to rear flue were required.

All vesta stoves allow for the chimney to be routinely cleaned by direct access through the stove door. This means unsightly access doors are eliminated and the clean lines of the wood stove is continued through the flue system.

Hearths

Vesta contemporary stoves should be situated on a non combustible hearth. We recommend granite or tiled hearths although many people opt for glass or a steel plate as an alternative. A full constructional hearth is not usually required were a stove shows that the heat underneath the appliance is less than 100 degrees. Care should be taken to ensure the floor can take the required loads prior to installation usually stove can weigh up to 150kg.

Surrounding Walls

The distance from vesta log burners to combustible materials should be 500mm. On adjacent walls fire plaster should be used to avoid cracking. Shielding can be used to protect surfaces from the appliance although it is best to speak to our technical office regarding the exact shielding for a given situation.

Plasma TV above wood burners

If you are looking to site a plasma TV above your contemporary stove then design is very important. We have a vast amount of experience in design of systems capable of this type of installation and can advise you accordingly. We have installed many woodburning stoves underneath plasma TV’s and providing the correct heat shielding and planning is used then this is perfectly safe and feasible.

Air bricks

Wood burners above 5kw in output require additional air supply by way of an air brick that is permanently open. We have a range of woodburners that DO NOT REQUIRE an airbrick they can be found here

Please see our installation instructions to see the exact size requirement of the airbrick for each contemporary wood burning stove

Do I need a hetas engineer?

The installation of a contemporary wood-burning stove is a controlled service under doc j of the building regulations. It is very simple to install the appliance your self providing you have a basic understanding of general building work.

The important point is that you must file a building notice with you local building control department. This is a simple process but normally carries a small charge.

Vesta engineers are available to offer advice in all aspects of the installation so please feel free to contact us.

 


Get In Touch

For our fastest response please use the contact form below.

Our response is normally within a 15 minutes during office hours

Contact Information

01704 821095
sales@vestastoves.co.uk

Opening Hours

Monday – Friday 9am-1pm 
Weekend – Closed

Address

Sevenoaks, 197 Hesketh Lane. Tarleton. PR4 6AT